| Error Code | Error contents |
| Indoor Unit | |
| A0 | Operation of protective uinit |
| A1 | Printer circuit board error |
| A3 | Drain level (33H) error |
| A6 | Fan motor locking , overload |
| A7 | Swing flap motor (MIS) error |
| A9 | Electronic expansion valve driver unit (Y1E) error |
| AF | Drain level (33H) error (Indoor uinit is stopping ) |
| AJ | Capacity setting error |
| C4 | Liquid pipe thermistor (R2T) error |
| C5 | Gas pipe themistor(R3T) error |
| C9 | Suction air thermistor (RiT) error |
| CJ | Remote contronler thermistor error |
| Oudoor Unit | |
| E0 | Operation of protective uinit |
| E1 | Printer circuit board error |
| E3 | operation of high pressureswitch |
| E4 | operation of low pressureswitch |
| E9 | Electronic expansion valve driver unit (Y1E) error |
| H3 | High pressure switch error |
| H4 | operation of low pressureswitch |
| H9 | Outdoor air thermistor (R1T) error |
| J1 | Pressure sensor error |
| J3 | Discharge pipe themistor (R3T) error |
| J5 | Suction pipe themistor (R3T) error |
| J6 | Heat exchanger thermistor (R3T) error |
| JA | Discharge pipe pressure sensor error |
| JC | Suction pipe pressure sensor error |
| JH | Oil thermistor error |
| L0 | Inverter error |
| L4 | Inverter cooling error |
| L5 | Short-circuit in compressor motor ,short-circuit in power unit |
| L8 | Short-circuit in compressor motor ,short-circuit |
| L9 | Locking in compressor |
| LA | Power unit error |
| LC | Transmission in compressor |
| P1 | Voltage unbalance ,open phase |
| P4 | Power unit temperature sensor error |
| System error | |
| U0 | Pressure drop due to insufficient refrigerant electronic expansion valve |
| U1 | Peverse phase ,open phase |
| U2 | Voltage error ,instantaneous power interruption |
| U4 | Transmission error between indoor unit and outdoor /Bs unit |
| U5 | Transmission error between remote contronller an indoor unit |
| U5 | Printer circuit board error or setting error of remote contronller |
| U7 | Transmission error between outdoor unit (unified cooling/heatting ,low noise operation) |
| U8 | Transmission error between remote contronller and sud remote contronller |
| U9 | Transmission error between another indoor unit and outdoor unit within same system |
| UA | Conbination error of indoor unit /BS unit /outdoor unit Conbination error of indoor unit /remote contronller Connected location error of BS unit |
| UC | Address duplication of center remote controller |
| UE | Transmission erroe between indoor unit and center remote contronller |
| UF | Wiring circuit does not corepond to refrigerant circuit |
| UH | Miss wiring |