Mitsubishi Heavy VRF

0 nhận xét

VRF systems

A VRF (Variable Refrigerant Flow) air conditioning system is a highly efficient system for cooling or heating air in a medium or large commercial building.

VRF 2-pipe heat pump system

A VRF (Variable Refrigerant Flow) air conditioning system comprises 1 outdoor unit connected to numerous (up to 48) indoor units.

In cooling mode the compressor makes refrigerant in the outdoor unit coil hot (which absorbs 'free' cooling from the outdoor air) and the expansion valves make the refrigerant in each indoor unit coil cold (which cools the indoor air).

In heating mode the refrigerant flow is reversed to produce hot refrigerant coils in the indoor units (which heat the indoor air). In a 2-pipe system all the indoor units are simultaneously either in cooling mode or in heating mode.

VRF 3-pipe heat recovery system

As in a 2-pipe system a VRF 3 pipe heat recovery system comprises 1 outdoor unit connected to numerous indoor units.

By an efficient refrigerant distribution controller, indoor units may take either hot or cold refrigerant from the system according to the requirements of the individual indoor room or zone. A room on the hot side of a building may take cold refrigerant to cool the air at the same time as a room on the cold side of the building takes hot refrigerant to heat the air.

By using refrigerant to recover heat from hot rooms to heat the air in cool rooms a heat recovery system can be even more energy efficient than a standard 2-pipe heat pump system.

Refrigerant

At the heart of an air conditioning system is refrigerant – a chemical substance which gets hotter as it is compressed from gas to liquid state, and gets colder as it is allowed to expand from liquid to gas state.

Early refrigerants were CFCs (ChloroFluoroCarbons, such as R12) and HCFCs (Hydro ChloroFluoroCarbons, such as R22) which caused damage to earth's ozone layer if they escaped (eg from pipe leaks or during poor servicing). Mitsubishi Heavy Industries has been a leader in developing air conditioning systems which use R410a, a modern 'synthetic' refrigerant which has zero ozone depletion potential.

Energy efficiency: CoP and EER

In cooling or in heating mode a VRF system is highly energy efficient; typically 1kW of electricity used by the compressor generates the equivalent of 3 or 4 or more kW of heating energy or cooling energy. The efficiency of the system depends on the design of many individual components, especially the compressor.

Efficiency in cooling is measured by EER (Energy Efficiency Ration): EER of 4 means the system gives 4kW of cooling energy using only 1kW of electrical power.

Efficiency in heating is measured by CoP (Coefficient of Performance): CoP of 4 means the system gives 4kW of heating energy using only 1kW of electrical power.

Mitsubishi Electric VRF

0 nhận xét
Industry-leading COP and System Flexibility

Highly efficient, ultra-quiet operation, low power consumption...

Our CITYMULTI systems utilize the innovative technologies, giving CITYMULTI units the same industry-leading COP (co-efficient of performance) classification. These highly efficient systems offer the merits of flexible installation, energy savings and ultra-quiet operation, all combined with the performance reliability and quality promised in the Mitsubishi Electric name.

CITYMULTI systems

 High Coefficient of Performance (COP) 

The latest energy-saving technologies are adopted for the CITYMULTI Series too. COP ratings are among the industry's best.

 Silent Operation 

Our outdoor units achieve high performance in low noise levels with a "low noise mode". Connected to the latest indoor units, the system is capable of offering a comfortable, silent interior space where occupants are not even aware of air conditioner operation.

 Choice of Indoor Units 

Select the best indoor unit to match room requirement and design needs. We have over 16 models in 8 type variations to choose from.
ndoor Unit Line-up of CITYMULTI R410A Series
R410A
Model Name Capacity (kw) / HP
P15 P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200 P250
0.8HP 1.0HP 1.3HP 1.6HP 2.0HP 2.5HP 2.8HP 3.2HP 4.0HP 5.0HP 5.6HP 8.0HP 10.0HP
Ceiling concealed
PEFY-P-
VMR-E-L/R
PEFY-P-
VMH-E
PEFY-P-
VMA-E
PEFY-P-
VMH-E-F
PEFY-P VMS1(L)-E
Ceiling cassette
PMFY-P-
VBM-E
PLFY-P-
VLMD-E
PLFY-P-
VCM-E
PLFY-P-
VBM-E
Ceiling suspended
PCFY-P-
VKM-E
Wall mounted
PKFY-P-
VBM-E
PKFY-P-
VHM-E
PKFY-P
VKM-E
Floor standing
PFFY-P-
VLEM-E
PFFY-P-
VLRM-E
PFFY-P-
VKM-E
PFFY-P-
VLRMM-E

Outdoor Unit Line-up of CITYMULTI R410A Series

Model Name Capacity (kw) / HP
P100 P125 P140 P200 P250 P300 P350 P400 P450 P500 P550 P600
4HP 5HP 6HP 8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP
CITYMULTI S Series
CITYMULTI Y Series
Refer to the table below
for models over 24HP (*1)
CITYMULTI Y(High COP)
Series

Refer to the table below
for models over 24HP (*2)
CITYMULTI ZUBADAN Y
Series
CITYMULTI WY Series
CITYMULTI R2 Series
Refer to the table below
for models over 24HP (*3)
CITYMULTI R2(High COP)
Series
CITYMULTI WR2 Series

Model Name Capacity (kw) / HP
P650 P700 P750 P800 P850 P900 P900 P900 P900 P900 P900 P900 P900
26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP 42HP 44HP 46HP 48HP 50HP
CITYMULTI Y Series (*1)
CITYMULTI Y(High COP)
Series (*2)
CITYMULTI R2 Series (*3)